Skip to content

LIS2DH12 Sensor

The lis2dh12 sensor platform allows you to use your ST LIS2DH12 ultra-low-power tri-axial accelerometer (datasheet) with ESPHome via the I²C bus.

LIS2DH12 is a high-performance accelerometer with selectable resolution (12-bit, 10-bit, or 8-bit) and configurable output data rates from 1 Hz to 5376 Hz.

This component provides acceleration data in m/s². XYZ axes can be calibrated and transformed to match the physical orientation of the sensor.

# Example I2C configuration
lis2dh12_i2c:
range: 4G
resolution: high
output_data_rate: 100Hz
update_interval: 10s
  • update_interval (Optional, Time): The interval for updating acceleration sensors. Defaults to 10s.

  • range (Optional, string): The range of the sensor measurements. One of 2G, 4G, 8G, 16G. Defaults to 2G which means it picks up accelerations between -2g and 2g.

  • resolution (Optional, string): ADC resolution mode. One of high (12-bit), medium (10-bit), low (8-bit). Defaults to high.

  • output_data_rate (Optional, string): Output data rate. One of 1Hz, 10Hz, 25Hz, 50Hz, 100Hz, 200Hz, 400Hz, 1620Hz, 5376Hz. Defaults to 100Hz.

  • calibration (Optional):

    • offset_x (Optional, float): X-axis zero position calibration, in m/s². From -4.5 to 4.5. Defaults to 0.
    • offset_y (Optional, float): Y-axis zero position calibration, in m/s². From -4.5 to 4.5. Defaults to 0.
    • offset_z (Optional, float): Z-axis zero position calibration, in m/s². From -4.5 to 4.5. Defaults to 0.
  • transform (Optional):

    • mirror_x (Optional, boolean): Mirror X-axis. Defaults to false.
    • mirror_y (Optional, boolean): Mirror Y-axis. Defaults to false.
    • mirror_z (Optional, boolean): Mirror Z-axis. Defaults to false.
    • swap_xy (Optional, boolean): Swap X and Y axis. Defaults to false.
  • All options from I²C Device. Default address is 0x19.

Acceleration data is available through sensors configuration. You can use shorthand notation like acceleration_x: "Acceleration X" or use regular notation. For regular notation only the name is required. All options from Sensor.

sensor:
- platform: lis2dh12_base
acceleration_x: Accel X
acceleration_y: Accel Y
acceleration_z: Accel Z
  • acceleration_x (Optional): X-axis acceleration, m/s².
  • acceleration_y (Optional): Y-axis acceleration, m/s².
  • acceleration_z (Optional): Z-axis acceleration, m/s².